Hanna Calcium Checker

Hanna

$65.00
(No reviews yet) Write a Review
SKU:
HI758
UPC:
426624678020
Adding to cart… The item has been added

Calcium Checker by Hanna

The handheld colorimeter eliminates the trouble of matching to a color chart by providing a direct saltwater calcium result in ppm CaCO3.

  • Removes the human error from testing
  • No need to count drops
  • Detects color changes your eyes cannot
  • No calibration required
  • Get easy, quick and consistent results
  • Accurate and affordable
  • Cost efficient: Once you purchase the Checker, reagents are sold separately saving money long term

DETAILS

Required for the development of calcium carbonate skeletons of coral reefs, calcium is a crucial component of marine waters. Designed as a more accurate alternative to chemical test kits, the HI758U provides quick, accurate results in a few easy steps.

FEATURES

· Easier to use and more accurate than chemical test kits

· Newly updated with 100μl mechanical pipette (HI731339P)

The HI758U Marine Calcium Checker HC® uses a 100 to 1 dilution for analysis and thus requires deionized or distilled water absent of calcium to function correctly. Calcium can be found in many freshwater sources and any amount present in the water used at the C1 phase can cause false high readings. In addition, many hobby grade reverse osmosis deionized water systems may not adequately remove calcium. This can vary based on the types of filters used, their effectiveness and frequency of replacement. Deionized water is recommended with low conductivity or pure vapor distilled water commonly found in most pharmacies.

Never use tap water to clean your cuvettes. This is especially important for the HI758U Marine Calcium Checker as calcium is commonly present in tap water and residual amounts present in the cuvette will elevate results produced by the Checker.

Calcium Checker Troubleshooting Tips

1.Never rinse cuvettes with tap water or saltwater

2.Use pure vapor distilled water from your local pharmacy at C1 phase. RODI water from home filtration units may not be suitable for this test as calcium can easily permeate through filter membranes. 

3.Clean cuvettes with distilled or deionized water absent of Calcium that is going to be used for C1 phase dilution. 

4.Measure out 9 ml of distilled or deionized water for C1 phase

5.Make sure no excess aquarium sample saltwater is on the tip of the pipette. Only administer the saltwater that is sucked into the pipette tip.


SPECIFICATIONS

Range

200 to 600 ppm

Resolution

1 ppm

Accuracy @ 25°C/77°F

±6% of reading

Light Source

LED @ 610 nm

Light Detector

silicon photocell

Method

adaptation of the Zincon method

Environment

0 to 50°C (32 to 122°F); RH max 95% non-condensing

Battery Type

(1) 1.5V AAA

Auto-off

after ten minutes of non-use

Dimensions

81.5mm x 61mm x 37.5mm (3.2" x 2.4" x 1.5”)

Weight

64 g (2.25 oz.)

Ordering Information

HI758 Calcium Checker is supplied with (2) sample cuvettes with caps, calcium reagent starter kit for 25 tests, dropper,1 ml syringe with tip, 100 microliter pipette with tip, plastic pipette, battery, instructions and quick start guide.

Warranty

1 year limited warranty